2-INSTALLATION INSTRUCTIONS
EXAMPLES OF CHIMNEYS
AISI 316 steel chimney with
double chamber insulated
with ceramic bre or similar
material, resistant to 400°C.
Refractory chimney with
insulated double chamber and
external lightweight concrete
cladding with cellular material
such as clay.
Traditional square-section clay
chimney with insulating empty
inserts.
Avoid chimneys with an
internal rectangular section
where the larger side is 1.5
times the smaller side (such as
20x40 or 15x30).
EXCELLENT GOOD POOR VERY POOR
For square or rectangular-section chimneys, the internal corners must be rounded with a radius of no less than 20 mm. For a rectangular
section, the ratio between internal dimensions must be ≤1.5.
The sections/lengths of the chimneys shown in the technical data table are guidelines for a correct installation. Any alternative
congurations must be suitably sized in accordance with the general method of calculation of UNI EN13384-1.
It is recommended for the ue duct to be equipped with a chamber to collect solid materials beneath the opening of the smoke duct,
which can be easily opened and inspected through an airtight door.
Should doubts arise regarding chimney performance or if its dimensions are dierent from those recommended, you
are strongly advised to have an installer, authorised by the manufacturer, perform an inspection and evaluate the
performance of the chimney.
The manufacturer declines all liability regarding product malfunctioning if this is attributable to a chimney that is
badly sized and installation does not comply with the stipulated requirements.