WOOD-BURNING STOVESTRIPE OVERNIGHTUSE AND INSTALLATION MANUAL ENTranslation of original instructions8901177000

Seite 2

82-INSTALLATION INSTRUCTIONSOUTDOOR AIR INLETDrill a hole on the outer wall close to the product with a minimum section of 100 cm² (13 cm in diameter

Seite 3 - INTRODUCTION

92-INSTALLATION INSTRUCTIONSCONNECTING THE PRODUCT TO THE CHIMNEYThe smoke outlet pipe is designed by the company for the smoke to be expelled towards

Seite 4 - SAFETY PRECAUTIONS

102-INSTALLATION INSTRUCTIONSTOP HOLE COVER AND REAR SMOKE OUTLET FITTING (ACCESSORY)Since there lies the possibility of having the smoke outlet on th

Seite 5

ABCD112-INSTALLATION INSTRUCTIONSCHIMNEYThe chimney is the fundamental element for smoke expulsion and must therefore comply with the following requ

Seite 6 - SPARE PARTS

122-INSTALLATION INSTRUCTIONSEXAMPLES OF CHIMNEYSAISI 316 steel chimney with double chamber insulated with ceramic bre or similar material, resis

Seite 7

AB1 mt0,5 mt132-INSTALLATION INSTRUCTIONSCHIMNEYPOTOften, if this factor is underestimated it hinders smooth “chimney system” operation.The draught

Seite 8

142-INSTALLATION INSTRUCTIONSIn the case of paired chimneys, the solid combustibility or upper storey chimneypot must be at least 50 cm higher than t

Seite 9

153-DIMENSIONS AND TECHNICAL CHARACTERISTICSSTRIPE OVERNIGHT STOVE* DIAMETER OF THE SMOKE OUTLETTechnical Dept. - All rights reserved - Reproduction i

Seite 10 - 2-INSTALLATION INSTRUCTIONS

163-DIMENSIONS AND TECHNICAL CHARACTERISTICSTECHNICAL CHARACTERISTICS STRIPE OVERNIGHTType of fuel Wood - logsHourly consumption 2,0 kg/h – 0,9 kg/hRe

Seite 11

174-INSTALLATION AND ASSEMBLYIMPORTANT!The product must be installed and connected to the chimney by a qualied technician or competent personnel in o

Seite 12

IITABLE OF CONTENTSTABLE OF CONTENTS ... IIINTRODUCTION

Seite 13

AB184-INSTALLATION AND ASSEMBLYThe product must always remain in a vertical position and handled solely with a forklift. Pay particular attention to t

Seite 14

194-INSTALLATION AND ASSEMBLYProceed with the installation as follows:• Place the two parts E on the base of the smoke tting.• Place part F on the

Seite 15

204-INSTALLATION AND ASSEMBLYASSEMBLING THE SIDE CLADDINGThe metal sides are not particularly dicult to install. The main precaution is to install th

Seite 16

214-INSTALLATION AND ASSEMBLYThen bring the two proles near the front panel making sure the ap of the panel enters the seat on the prole.HOUSED PRO

Seite 17 - STRIPE OVERNIGHT STOVE

224-INSTALLATION AND ASSEMBLYThen bring the rear panel and enter it in the pins found on the lower part of the product.PINS

Seite 18

234-INSTALLATION AND ASSEMBLYOnce the above is completed, block the front and rear panels and proles with the two fastening plates.As shown in the g

Seite 19 - 4-INSTALLATION AND ASSEMBLY

244-INSTALLATION AND ASSEMBLYASSEMBLING THE TOPPlace the top on the upper part of the product making sure the spacers on the bottom part of the top en

Seite 20

255-OPERATIONSTART-UP PRECAUTIONSMake sure you have read and fully understood the contents of this instruction manual.Remove all components that could

Seite 21

265-OPERATIONA high percentage of moisture causes condensation in the smoke duct, thereby causing an alteration to the draught and generating smoke an

Seite 22

275-OPERATIONADJUSTING THE AIR WITH THE PUSH-PULL SYSTEM Press the air adjustment knob, which will slightly emerge from its seat thanks to a spring an

Seite 23

1INTRODUCTIONDear Customer,thank you for having chosen a product from our Wood-burning range.Products manufactured with OYSTER technology, do not cons

Seite 24

285-OPERATIONFIRST IGNITIONA NOTE REGARDING PAINT EXHALATIONIt is recommended to air the room before the rst start-up to evacuate any smells and/or f

Seite 25

296-MAINTENANCE AND CLEANINGAll the cleaning operations of all parts must be performed with a completely cold product.CLEANING PERFORMED BY THE USER C

Seite 26

306-MAINTENANCE AND CLEANINGCLEANING STAINLESS STEEL AND SATIN-FINISHED SURFACES These surfaces do not usually require any specic treatment besides n

Seite 30

07/09/2012REV.08901177000MCZ GROUP S.p.A.Via La Croce n°833074 Vigonovo di Fontanafredda (PN) – ITALYTelephone: 0434/599599 r.a.Fax: 0434/599598Intern

Seite 31 - 6-MAINTENANCE AND CLEANING

21-WARNINGS AND WARRANTY CONDITIONSSAFETY PRECAUTIONS• Installation, functional verication and maintenance must only be performed by qualied or aut

Seite 32

31-WARNINGS AND WARRANTY CONDITIONSINFORMATION• Please contact the retailer or qualied personnel authorised by the company to resolve a problem.• C

Seite 33

41-WARNINGS AND WARRANTY CONDITIONSINTERVENTION REQUESTThe company declines all liability if the product and any other accessory is used incorrectly o

Seite 34

52-INSTALLATION INSTRUCTIONSThe requirements stipulated in this chapter refer to the regulations of the Italian installation standard UNI 10683. In an

Seite 35

62-INSTALLATION INSTRUCTIONSSAFE DISTANCESSTRIPE OVERNIGHTNon-ammable walls Flammable wallsA = 5 cmB = 10 cmA = 5 cmB = 20 cm*LEAVE AN APPROPRIATE DI

Seite 36

72-INSTALLATION INSTRUCTIONSREAR VIEW OF THE STRIPE PRODUCT:1) COMBUSTION AIR INLETCONNECTING THE COMBUSTION AIR INLET PIPEThe combustion air inlet do